|
VOLUME
I
PAPERS:
SESSION OPEN: OPENING
Biomedical Engineering in Europe: Where should the
emphasis be put?
Beneken J. E. (pag. 3)
SESSION GIUV1: GlUV I
Investigation of Peripheral Circulation at Major Swedish
Hospitals
Volkmann R., Fagrel B., Holm J. (pag.7)
Methodological
Aspects on Venous Plethysmography
Vokmann R., Bergerheim T, Holm J. (pag. 9)
Organisation
of the Vascular Laboratory
Taft A. (pag. 3)
The
Vascular Diagnostic Laboratory in the United States
Neumyer M.M. (pag.15)
The
Vascular Laboratory in Italy
Borgatti F., De Fabritiis A., Emiliani I., Filippini
M., Martignani A. (pag.19)
Ultrasound
for Vascular Application in Neurology
Sliwka U., Rautenberg W., Hennerici M. (pag.23)
Venous
Testing: Medical, Social and Economic Impact
Nicolaides A.N. (pag.27)

SESSION
GIUV2: GlUV II
Color Doppler in Evaluation of Renal Artery Disease
Amalo A., De Fabritiis A., Borqatti F. (pag.31)
Experimental
Comparison of In Vitro Carotid Ultrasound Images with
Actual Digitized Anatomical Sections
Righi D., Capineri. L., Castellini G., Gori F.
(pag.35)
New
Findings in Non Invasive Diagnostic Techniques of
Deep Venous Thrombosis
Antignani P.L. (pag.39)
The
Early Alteration of Shear Stress on the Arterial Wall
in Patients with Vascular Risk Markers and without
Vascular Disease: Evaluation by Ecoduplex Scanner
Signorelli S.S. (pag.43)
Ultrasound
Detection of Venous Thrombi
Arnoni F., De Stefano A. (pag.49)
Ultrasound
Investigations in the Postoperative Control of Arterial
Graft of the Lower Limbs
Gossetti B., Martinelli 0., Fornasin F.A., Irace
L., Benedetti-Vatentini F. (pag.5)

SESSION
NEU-SPl: ELECTROMYOGRAPHY AND BIOELECTRICAL PHENOMENA
Acousticographic and Electromyographic Patterns of
Verbal Motor Control
Pinelli P., Ceriani F., Miscio G., Pisano F. (pag.57)
Computerized
Analysis of Speech and Electromyographic Patterns
of Speech Motor Control
Grandori F., Pinelli P., Ceriani F., Miscio G.,
Pisano F., lnsalaco S., Ravazzani P. (pag.61)
Gaze
Control in Man
Schmid R., Zambarbieri D . (pag.65)
Modelling
of Surface EMG during lsokinetic Test
Cesarelli M., Castaldo R., Pepino A., Spiezia A.,
Bracale M., Marasco E., Fazioli G. (pag.69)
Separation
of Travelling from Non-Travelling Components in Surface
Myoelectric Signals
Rubio J., Merletti R., Fan Y. (pag.73)

SESSION
PHAR-M: PHARMO KINETIC MODELLlNG
A Multi-Region Distributed Parameter Model for
Measuring Glucose Transport in the Human Skeletal
Muscle from lndicato Dilution Data
Vicini P., Saccomani MP., Bonadonna R., Cobelli
C. (pag.77)
Evaluation
of Calcium Kinetics as a Tool for Bone Turnover in
Comparison to Biochemical Parameters
Werner E., Roth P., Spielberqer I., Hansen C.H.
(pag.81)
Modelling
of Lidocaine-MEGX Kinetics to Assess Impairment of
Liver Function
Hovorka R., Fried M., Jones E.A., Di Bisceglie
A.M., Carson E.R. (pag.85)
Pharmacometric
Modelling by using Bayesian Networks
Bellazzi R., Berzuini C. (pag.89)
Physiological
and Pharmacokinetic Modelling of Trace Element Metabolism
Hansen CH., Roth P., Werner E., Cantone M.C., de
Bartolo D., Gambarini G., Molho N., Pirok L. (pag.93)

SESSION
BlOMAT1 : BlOMATERlAL AND PROSTHESES
Blends of PVA with Collagen, Gag, Fibronectin
as New Bioartificial Materials. I. The System PVA
and Collagen
Giusti P., Lazzeri L., Barbani N., Narducci P.,
Palla M., Lelli L. (pag.97)
Development
of an Implantable Neural Connector for Limb Prostheses:
In Vitro Investigations
Cocco M., Toro M., Migliorini P., Bongioanni P.,
Sabatini A.M., Dario P., Sacchetti R., Schmidl H.
(pag.101)
Microbial
Colonization of Catheters Explanted from Nephropathic
Children
Gelosia A., Baldassarri L., Mignozzi M., Fiscarelli
E., Rizzoni G., Donelli G. (pag.105)
Shape-Memory
Alloy Intravascular Endoprosthetic Stents: Design
and In Vitro Tests
Montesi M.C., Valeggi R., Trivella M.G., Bergamasco
M., Sakedo F., Dario P. (pag.109)
The
Effect of Temperature on the Dimensional Variation
of Composite Resins
Fano V., Ortalli I. (pag.113)
Tribological
Behaviour of UHMWPE Acetabular Cups against Differently
Treated Ti-6AI-4V Prosthetic Heads
Cigada A., Brunella M.F., Pezzi D. (pag.117)

SESSION
BIOSPl: BIOMEDICAL SIGNAL PROCESSING I
A New Class of Digital Filters with Applications
in Biomedical Signal Processing
Varri A., Neejarvi J., Neuvo Y. (pag.121)
A
Tool to Control Biosignal Processing with an Application
to Analyse Esophageal Function
Faust U., Liu J. (pag.125)
Adaptive
Identification of Visual Evoked Potentials, Application
to Multiparametric Stimulation
Brikou A.K., Moustakides G.V., Bezetianos A., Papathanasopoulos
P. (pag.129)
Analogical
and Digital Filtered Acquisition of Fetal Electrocardiogram
by Transabdominal Recording
Bortone A., Cicinelli E., Incampo G., Carbonara
L., Schonauer S., Rizzon P. (pag.133)
Improvement
of the Diagnostic Sensitivity of the BAEP Amplitudes
after Normalization for Skull Thickness and Head Size
Niklforidis G., Katisojannis C., Karamitsos D.
(pag.137)
Spectral
Analysis of Dystonic Movements with Application of
Linear Models
Scholz U., Wissel J., Mainardi L., Poewe W. (pag.141)
The
European ST-T Database: A Standard for Evaluating
Systems for the Analysis of ST-T Changes in Long-Term
ECG
Taddei A., Distante G., Emdin M., Pisani P., Noody
G., Zeelenberg C., Marchesi C. (pag.145)

SESSION
MED_DM1: MEDICAL DATA MANAGEMENT I
Diagnostic Procedures based on a New Medical Imaging
Concept
Anastassopoulos G., Kotsopoulos S., Lymberopoulos
D., Goumas P. (pag.149)
Networked
Portable Digital Radio for the Hospital Environment
Mitchell C.M., Matthews J.G.W., Evans N.E., Black
N.D. (pag.153)
Object-Oriented
Generator of Documentary Banks Application to Head
Trauma
Froment J.C., Azencot J., Unterreiner R., N'Gbesso
R. (pag.157)
Progressive
Image Transmission Methods for Biomedical Data Bases
Access
Argenti F., Cappellini V., Venetsanopoulos A.N.
(pag.161)
Unified
Medical Data Management on Medical Workstations
Anastassopoulos G., Lymberopoulos D., Kotsopoulos
S., Kokkinakis G. (pag.165)

SESSION IM_PRO1: MEDICAL IMAGING I
A Computer Assisted Method for Image Feature Extraction
and Analysis based on B-spline Algorithm
Marchetti A., Guo Y.H., Azzarelli L., Chimenti
M. (pag.169)
Automatic
Detection of Left Ventricular Endocardium on Ultrafast
Tomodensitometric Images
Bastide N., Harment A., Dumee P., Mousseaux E.,
Peronneau P. (pag.173)
Correcting
Local Distortion for Automatic Comparison of Electrophoresis
Images
Wang A., Neuvo Y. (pag.177)
Non-Invasive
Hemodynamic Cerebrovascular Parameter Evatuation from
Input Impedance Ultrasound Measurements
Evangelisti A., Powalowski T., Trawinski Z. (pag.181)
Some
Preliminary Notes about the Use of 'CAD' Structures
for the Pre-operative Planning of lntertrocantheric
Osteotomies
Pepino A., Mosca A., Cesarelli M., Di Salle F.,
Bracale M. (pag.185)
Spatial
Characterization of Non Regular Anatomical Structures
Caramella D., Braccini G., Salvetti O., Guelfi
R., Masoni M. (pag.189)

SESSION
NEU_SP2: EEG AND EVOKED POTENTIALS
A Model for the Magnetic Stimulation of Human
Cortex and Peripheral Nerves
Ravazzani P., Grandoni F., Piavani A., Vardanega
M.G. (pag.193)
A
Study of Slow Changes in the EEC Activity during Sleep
Barcaro U., Bizzari M., Bonanni E., Denoth F.,
Murri L, Navona C. (pag.197)
A
Study of Surface Wave Propagation in the CNV
Barcaro U., Denoth F., Navona C., Versari A., Zappoli
R. (pag.201)
Analysis
of Human Brain Evoked Potential on a Single Trial
Topographic Basis
Liberati D., Cerutti S., Comi G., Locatelli T.
(pag.205)
Automatic
Epileptic Spike Detection by Median filtering and
Simple Arithmetic Sharp Transient Detector: A Clinical
Evaluation
Krajca V., Pettranek S., Patakova I., Ondruska
V. (pag.209)
Brain
Synergies in Simultaneous Bisensory Stimulation: Recognizing
and Modelling Cortico-Cortical Interactions
Liberati D., Brandazza P., Cerutti S., Cursi M.
(pag.213)
Comparison
between two Techniques for Recording Otoacoustic Emission
Ravazzani P., Grandori F. (pag.217)
Electric
Induced Field Stimulation Technique using Toroidal
Coils. An Application to Evoked Potentials
Ferrero J.M., Robles M., Guijarro E., Sàiz
J., Ferrero J.M.Jr., Mocholì A. (pag.221)

SESSION
PHY_MOD1: PHYSlOLOGlCAL MODELLING I
A Comparative Evaluation of Models for the Aortic
Input Impedance
Avanzolini G., Cappello A., Gnudi G. (pag.227)
A
Computer Study on Feedback Control of Glucose Concentration
through Subcutaneous Sensors
Fabietti P.G., Filippucci F ., Cruciani P., Sarti
E. (pag.231)
A
Mathematical Model to Study the Relationship between
the Haemodynamics of the Main Cerebral Areas
Fabbri G., Ursino M. (pag.235)
Hormone
Secretion Rate Estimation via Spectral Analysis and
Deconvolution of the Blood Concentration
De Nicolao G., Liberati D. (pag.239)
Improvement
of Numerical Interpretation of Healthy Newborn Human
Blood Viscometric Measurements
Martino R., Trevisan F., Cesaro M., Cattozzo V.,
Cason C., Bettini V., Masiero G. (pag.243)
Numerical
Simulation of Stress inside a Skin-like Tactile Sensor
Colli Franzone P., Germagnoli F., Guerri L., Magenes
G. (pag.247)
Theoretical
Implications of Capacity Vessel Control
Ursino M., Belardinelli E ., Di Gianmarco P .,
Antonucci M. (pag.251)

SESSION
BlOMCH1: GAIT ANALYSIS
A Large Platform for the Detection of Foot-To-Floor
Pressure Distribution
Macellari V., Giacomozzi C., Torre M. (pag.255)
Accuracy
of the Determination of the Instantaneous Helical
Axis for In-Vivo Applications
Fioretti S., Leo T., Maurizi M. (pag.259)
An
Algorithm for Automatic Movement Detection by means
of Professional TV Camera
Cukusic Z., Cecic M., Zanchi V. (pag.263)
Evaluation
Of Asymmetry of Hemiplegic Gait using Electromyographic
Phasic Activity
Chen J.J., Liou J.J., Hwang I.S., Lin S.I., Huseih
T.C. (pag.267)
Gait
Evaluation Method in Patients with Implanted Hip Prostheses
Stanic U., Herman S., Merhar J., Demsar H., Kljajic
N., Malezic M., Vrtacnik P., Acimovic-Janezic R.,
Kljajic M. (pag.271)
Interpretation
of Preoperative and Post-operative Results of Gait
in Patients with Total Hip Replacement
Herman S., Stanic U., Merhar J., Demsar H., Kljajic
N., Malezic M., Vrtacnik P., Acimovic-Janezic R.,
Kljajic M. (pag.275)
Kinematics
of the Lower Limb Joints during Gait
Cheze L., Gignoux P., Dimnet J., Carret J.P. (pag.279)
Optimum
Proportions of Human Arm Mechanism with respect to
its Workspace
Lenarcic J., Umek A. (pag.283)

SESSION
CEL_EN: CELLULAR ENGINEERING
Analysis Of Micromechanical Parameters of Erythrocytes
- A Cell Bioassay for Indirect Examination of Drug
Effects on Red Blood Cells
Artmann G. (pag.287)
Aspiration
Experiments of Passive Leucocytes Into Micropipettes
Bucherer C., Geiger S., Lacombe C., Lelievre J.C.
(pag.293)
Biomimicry
for Chemical and Physical Sensing
Rolfe P. (pag.297)
Cellular
Engineering and Burn Treatments from a Dermal Substrate
to a Reconstructed Skin
Damour O., Echinard E. (pag.301)
Cellular
Engineering: The Role of the Engineer in the Biological
Evolution
Nerem R.M. (pag.307)
Characteristic
Locations of Residues in Globular Proteins
Ruggiero C., Sacile R. (pag.309)
Coculture
of Endothelial Cells with Smooth Muscle Cells in a
Collagen Matrix
Ziegler T., Nerem R.M. (pag.313)
Image
Analysis of Cell Movement in Predicting Biological
Behaviour
Komotowski D., Kunz M. (pag.317)
Micromechanical
Behaviour of Neutrophils Via Micropore Filtration
Approach
Nikita K.S., Uzunoglu N.K., Koutsouris D. (pag.321)
Modulation
of Cell Cycle by Low Level Direct Current in Cancer
Vodovnik L., Miklavcic D., Sersa G. (pag.225)
Modulation
of Single Channel State Transitions
Salvaggio A. (pag.329)
Moleculle
Diffusion Simulated in Computer Modelled Brain Tissues
Lipinski H.G. (pag.333)
Organised
Protein Films
Ahluwalia A., De Rossi D. (pag.337)
Red
Blood Cell Properties Studied by Ultrasonic Interferometry
Razavian M., Gamghi N., Coulibali H., Guillet R.,
Beuzard Y., Boynard M. (pag.341)
The
Bio/Electronic Interface: State of the Art and Prospects
Grattarola M., Martinoia S., Cambiaso A. (pag.345)

SESSION
MED_IN: MEDICAL INSTRUMENTATION
A New CCD Microscope and its Application to the
Analysis of the Effects of Nitroglycerin on Porcine
Coronary Venules
Yada T., Kimura A., Yamamoto T., Hiramatsu O.,
Goto M., Ogasawara Y., Tsujioka K., Kajiya F. (pag.349)
A
New Microcomputer Controlled Solid-State Ocular Fluorophotometer
Hamid O., Jones D.P (pag.353)
A
Proximity Communication Link for Physiological Data
Acquisition
McCreesh Z., Evans N.E. (pag.357)
Evaluation
of Chest Volumes during Respiration
Ferrigno G., Carnevali P., Molteni F., Pedotti
A. (pag.361)
FRP
II: Wide Range High Resolution Low Cost Blood Velocity
Profiler
Bardelli M., Carretta A., Di Paolo G., Dotti D.,
Dotti F., Lombardi R. (pag.365)
Portable
Electroventilation
Dempsey G.J., Cochrane D., Anderson J., Allen D
., Adgey J. (pag.369)
Study
of the Electrode-Skin Interface Behaviour in Switching
Transients
Ferrero J.M.Jr., Saiz J.F., Ferrero J.M., Robles
M., Guijarro E., Arnau A. (pag.373)

SESSION
CARDlO1: CARDIOVASCULAR MODELLING AND MEASUREMENTS
Computer Simulation of Flow Phenomena in Distensible
Arterial Bifurcation Models
Perktold K ., Peter R.O., Gurtl R. (pag.377)
Local
Point Spread Functions (PSF) in Positron Emission
Tomographic (PET) Slices
Labbé C., Rouseet O., Lavenne F., Landais
P., Cinotti L. (pag.383)
Model
of the Carotid Arterial Impedance in the Pig
Burattini R., Montanari L., Mulligan L.J., Gross
D.R. (pag.387)
Regional
Myocardial Function Curve of the Ventricle
Kondoh Y., Sugawara M., Nukano K., Uchida K. (pag.391)
The
Measurement of Electrical Myocardial Impedance as
a Method for Rejection Diagnosis after Heart Transplantation
Mueller J., Warnecke H., Cohnert T., Nelson B.,
Hetzer R. (pag.395)

SESSION
EL_STIM1: ELECTRlCAL STIMULATION
A Neurophysiological Model of the Long-Term Antispastic
Effect of Therapeutic Electrical Stimulation (TES)
in Hemiplegic Patients
Alfieri V. (pag.401)
A
Voice Activated FES System for the Restoration of
Hand Movements in Plegic Subjects
D'Alessio T., Bonato P., Capozza M., Falaschi A.,
Inghilleri M., Modugno A. (pag.408)
Effects
Of the Electric Current on Partial Oxygen Tension
in Wound Surrounding
Likar B., Poredos P., Preseren M., Klesnik M.,
Vodovnik L. (pag.409)
Electric
and Magnetic Stimulation of Human Peripheral Nerves
Nilsson J., Panizza M., Roth B.J., Basser P.J.,
Cohen LG., Caruso G., Hallett M. (pag.413)
Self-Controlled
FES System for Paraplegics
lsakov E., Mizrahi J. (pag.417)
Sensory
Feedback for Enhancing FES in Spinal Cord Injured
Patients
Kralj A., Les M., Munih M., Bajd T., Turk R. (pag.421)

SESSION
ART_ORG: CARDIOVASCULAR IMPLANTABLE DEVICES
Arterial Graft Shape and Shear-Stress at the Wall
Cavalcanti S., Belardinelli E. (pag.425)
Computer
Flow Simulation on the Performance of Parallel Corotating
Disks as a Heart Assist Device
Pinotti M., Rosa E.S. (pag.429)
Distributed
Effects of a Stenosis along an Artery
Cavalcanti S., Belardinelli E. (pag.433)
Prosthetic
Heart Valve Evaluation In Vitro: Technical and Methodological
Aspects of Pulsatlle Testing
Barbaro V., Daniele C., Grigioni M., Palombo A.
(pag.437)
Research
and Development on Implantable Total Artificial Heart
(TAH) in Japan
Kazuhuko A., lwao F., Kou L., Kunihiko M., Tsuneo
C., Yusuke A. (pag.441)

SESSION
HRV: HEART RATE VARIABILITY
Approximate Dimension and Entropy to Measure the
Complexity of Heart Rate Variability in Healthy Subjects
Balocchi R., Michelassi C., Carpeggiani C. (pag.445)
Estimation
of the Power Spectrum for the Analysis of Variability
with Time-Frequency Distributions
Pola S., Emdin M., Macerata A., Varanini M., Conforti
F., Carpeggiani C., Marchesi C. (pag.449)
Modelling
the Baroreflex: A Matter of Balance
TenVoorde B.J., Rompelman O., Faes TH.J.C. (pag.453)
Parametric
Spectral Analysis and Chaotic Modelling of Cardiovascular
Variability Signals
Cerutti S., Signorini M.G., Bianchi A., Lissandrello
F., Solari S., Montefusco A., Furlan R., Malliani
A. (pag.457)
Quantitative
Correlation between EEG and HRV Signal during Different
Sleep Stages
Bianchi A.M., Schoulz U., Cerutti S., Kubicki S.,
Padovani P., Panizza F. (pag.461)
Time-Variant
Spectral Estimation Algorithms for the Study of Transient
Ischemic Episodes
Mainardi L., Bianchi A., Stagni A., Signorini M.G.,
Bertinelli M., Cerutti S. (pag.465)

SESSION
SURG: TECHNOLOGY FOR SURGERY
A New Bleeding-Controlled Bladder Irrigation System
for Post-operative Treatment after Endoscopic Surgery
Kreutzig T., Sommerkamp H., Bruckner B., Hakenberg
O., Popken G., Koppermann U. (pag.469)
A
New Technique to Control Biliary Tract Functions after
Sphincterotomy
Baxa P., Cherubini M., Walcher G. (pag.473)
Analysis
of the Accuracy of a Robotic Procedure for Knee Arthropiasty
Martelli S., Fadda M., Dario P., Marcacci M., Visani
A. (pag.477)
Co
Laser Angioplasty System
Kikuchi M., Arai T., Mizuno K., Takeuchi K., Utsumi
A., Akei Y. (pag.481)
Revolutional
Challenge for Future Medicine by Laser Application
Kazuhiko A. (pag.485)
Surgical
Planning in Virtual Reality, by means of an Instrumented
Toolholder
Giorgi C., Beltrame F., Luzzara M., Marcenaro P.
(pag.489)
The
Use of CAD Techniques for the Preoperative Planning
of lntertrocantheric Osteotomies
Pepino A., Mosca A., Cesarelli M., Di Salle F.,
Bracale M. (pag.493)

SESSION
HRVP: CARDIOVASCULAR VARIABILITY SIGNAL
A Study of Blood Pressure Control via a New Method
for the Analysis of the Blood Pressure Signal
Almog Y., Akselrod S. (pag.497)
Are
Main Spectral Features of the Arterial Pressure Variability
Signal Modified when Measurements are taken from a
Non-Invasive Finger Blood Pressure Monitor?
Pinna G., Maestri R., Di Cesare A., La Rovere M.T.,
Mortara A. (pag.501)
Role
of Baroreceptors in Controlling Long Term ModuIations
of Blood Pressure and Pulse Interval
Di Rienzo M., Castiglioni P., Parati G., Omboni
S., Ramirez A.J., Pedotti A. (pag.505)
Time-Qualified
Prediction Limits for Circadian Blood Pressure Variability
in Clinical Health
Fernandez J.R., Hermida R.C., Ayala D.E., Cid V.,
Mojon A. (pag.509)

SESSION
IM_PRO2: MEDlCAL IMAGING II
3D Reconstruction of Vascular Structures from
two Angiograms by Simulated Annealing
Pellot C., Herment A., Sigelle M., Horain P., Peronneau
P. (pag.513)
Integrating
Statistical and Spatial Information in Medical Image
Segmentation
Carreira M.J., Cabello D., Mosquera A., Penedo
M.G. (pag.517)
Measurement
of the Flow Field in a Normal Left Ventricle using
Magnetic Resonance Phase Velocity Encoding
Walker P.G., Scheidegger M.B., Cranney G.B., Pohost
G.M., Yoganathan A.P. (pag.521)
New
Realization of the Image Reconstruction
Bogorodzki P., Piatkowski A. (pag.525)
Quantitation
of Regional Myocardial Blood Flow by Contrast Echocardiography
Mor-Avi V., David D., Bitton Y., Keselbrener L.,
Akselrod S. (pag.529)

SESSION
REHAB1: REHABILITATlON ENGINEERING
Communication and Environment Control System for
Quadraplegics
Oberle A., Bach G., Gauthier G.M., Vercher J.L.,
Dollfus P. (pag.533)
Left
Ventricle Boundary Detection with Kohonen Maps
Manhaeghe C., Lemahieu I., Vogelaers D. (pag.537)
Model
of an Experiment Design in Rehabilitation and Physical
Activity Studies
Bogataj U., Kljajic M., Gros N., Acimovic-Janezic
R. (pag.541)
Optimization
of the Robotized System 'MASTER' after the Clinical
Evaluation
Detriche J.M., Lesigne B. (pag.545)
Research
into Optimising Hand and Body Function for Tasks in
Everyday Living -The Development of a Range of 'Easy
Use' Saucepan Handles
Brown F.R., Torrens G.E., Wright D.K. (pag.549)
Restoration
of Upper Limb Function to Tetraplegics using Neural
Networks and a Voice Processing System
Cliquet A.Jr., Mendeleck A., Quesnel D.R.F., Sovi
F.X., Felile P.Jr., Oberg T.D., Lemos G.J.P., Guimaraes
E.A., Quevedo A.A.F. (pag.553)

SESSION
CLDEV1: BIOMEDICAL AND CLINICAL ENGINEERlNG
A European course on Biomedical Engineering and
on Medical Physics
Proimos B.S. (pag.557)
Activities
of the Centre for Information and Evaluation of Biomedical
Equipment of Trieste
Bravar D., Fonda S., Giribona P. (pag.561)
An
Experimental Set-Up for Measuring the Output of Extra-Corporeal
Shock Wave Lithotripters
Buizza A., Dell'Aquila T., Giribona P., Spagno
C. (pag.565)
Decision
Support System for the Management of Biomedical Equipment
at a Regional Level
Lamberti C., Marsili A., Carota L., Roversi E.,
Gnudi G., Avanzolini G. (pag.569)
Electrical
Safety in Operating Room Monitors. Measures and Controls
Sanchez J.C., Garcia T., Sanz F., Sanz J.L. (pag.573)
The
Clinical Engineering Department as a Private Enterprise
within the Health Care System
Oberg P., Bostrom U., Strom I. (pag.577)

SESSION
DIA-SYS1: DIAGNOSTIC SYSTEMS
A Prototype System for the Continuous Monitoring
of Meconium in Amniotic Fluid during Labour
Genevier E.S.G., Danielian P.J., Steer P.J. (pag.581)
Electric
Current Distribution and Temperature Evaluation under
Noninvasive Current Electrodes
Lambert H.L., De Mey G.A., De Bisschop F.R., Vanderstraeten
G.G., De Cuyper H.J. (pag.585)
Feasibility
Study of a Method for Monitoring Anaesthetic Depth
Rosenfalck A., Norregaard Christensen K., Eckhart
Thomsen C., Gade J. (pag.589)
Quantitative
Estimation of Visual Fatigue through Analysis of Pupillary
Light Response
Hoshino K., Saito M. (pag.593)
Respiratory
Impedance during Conventional Mechanical Ventilation
Barbini P., Cevenini G., Massai M.R., Ursino M.
(pag.597)
Volume
Flow Rate Measurement in Fleisch Pneumotachograph
Considering Heat Exchange
Barbosa R.B., Figueiredo A.M.D., Giannella-Neto
A. (pag.601)

SESSION
TECH_A1: TECHNOLOGICAL ASSESMENT 1
Measurement of the Output of Commercial Extra-Corporeal
Shock Wave Lithotripters for Kidney Stones
Buizza A., Dell'Aquila T., Giribona P., Spagno
C. (pag.605)
Measuring
Health Benefits in Technology Assessment
Hutton J. (pag.609)
Program
for the Assessment of High-Technology Health Care
Devices in Japan
Kikuchi M. (pag.615)
Prosthetic
Heart Evaluation In Vitro: The FDA Interlaboratory
Comparison Testing Protocol Applied on Two Different
Pulse Duplicators
Barbaro V., Daniele C., Grigioni M., Palombo A.
(pag.619)
Quality
Control of Mammographic Units in Greece
Panayiotakis G., Giakoumakis E., Flioni-Vyza A.,
Xenofos S., Proimos B. (pag.623)
Study
of Phantoms for the Validation of a Fluorescence Detection
System Using a Krypton Laser: Application to Cancer
Diagnosis in Phodynamic Therapy
Diller M.L., Granjon Y., Guillemin F., Meunier-Reynes
A., Yvroud E. (pag.627)
Subjective
Quality of Care and Safety and the Use of Medical
Devices
Persson J., Ekberg K. (pag.631)
Technology
Assessment and the Medical Equipment Industry
Hutton J. (pag.635)
Why
Technology Assessment?
Persson J. (pag.637)

SESSION
BIOMAT2: CELLULAR AND TlSSUE BIOMECHANICS
Cyclic Stress Fatigue Changes in Arteries
McCord B., Aoki T., Ku D. (pag.639)
In-Vitro
Electric Properties of Femoral Bone
De Mercato G., Garcia Sanchez F.J. (pag.643)
Micromechanical
Behavior of Neutrophils Via Micropore Filtration Approach
Nikita K.S., Uzunoglu N.K., Koutsouris D. (pag.647)
The
Influence of Hydration and Preconditioning on the
Failure of Stratum Corneum
Nikolopoulos C., Barbenel J.C. (pag.653)

SESSION
US_VASC: ULTRASOUNDS IN CARDIOVASCULAR SYSTEM I
Analysis of Blood Velocity into Myocardium during
Coronary Artery Stenosis by 20 MHz 80 Channel Pulsed
Doppler Velocimeter in Dogs
Kajiya F., Kimura A., Yada T., Hiramatsu O., Tokuda
C., Ogasawara Y., Goto M., Tsujioka K. (pag.657)
Cardiac
Output Measurement with a New Perivascular Multi-element
Doppler Transducer
Kim W.Y., Pedersen E.M., Somod L., Hasenkam J.M.,
Nygaard H., Paulsen P.K. (pag.661)
New
Developments in Cardiac Ultrasound Technology
Bom N., De Kroon M.G.M. (pag.665)
Possible
Improvement of Color Flow Images by Adaptive Estimation
of the Mean Frequency of the Doppler Signal
Herment A., Peronneau P., Pellet C. (pag.669)
Quantitative
Mapping of Turbulent Stresses Downstream of Mechanical
Aortic Valve Phrosthesis in Humans using Perivascular
Doppler Ultrasound
Nygaard H., Paulsen P.K., Hasenkam J.M., Pedersen
E.M., Rovsing P.E. (pag.673)
Spatial
and Temporal Development of Velocity Profiles in the
Porcine Main Pulmonary Artery
Hasenkam J.M., Somod L., Pedersen E.M., Kim W.Y.,
Rovsing P.E. (pag.677)
Transverse
Doppler: A Novel Ultrasound Technique for Accurate
Flow Velocity Measurements
Tortoli P., Guidi G., Valgimigli F., Atzeni C.,
Newhouse V.L. (pag.681)

SESSION
BIOMCH2: BIOMECHANICS
Analysis of the Influence of Femur Resection in
Hip Arthroplasty
Bignardi C., Calderale P.M. (pag.665)
Biomimetic
Approaches to the Design of Materials for Artificial
Haptics and Manipulation
De Rossi D., Domenici C., Chiarelli P., Canepa
G. (pag.669)
Experimental
and Numerical Methodologies for Dental Implants Evaluation
Calderale P.M., Rossetto M. (pag.693)
Muscle
Bending Profiles in Different Body Postures
Munih M., Kralj A. (pag.697)
The
Biomechanics of Pin-Bone Interface of Three External
Fixation Pins on Iliac
Liu J., Chang G.L., Chang W.S., Lai K.A., Chou
Y.L. (pag.701)
The
Use of Digitised Videofluoroscopic Images in the Analysis
of Spinal Mechanics In-Vivo
Kondracki M., Breen A., Allen R. (pag.703)
Three-Dimensional
Orifice Geometry Correction is Required for Calculating
Regurgitant (Valvular) Flow Rate by Proximal Convergence
Yoganathan A.P., Cape E.G., Levine R.A., Thomas
J.D., Weyman A.E. (pag.707)
|